KS321 Hazardous Areas - Enclosure
CFR(s): NFPA 101

Hazardous Areas - Enclosure 2012 EXISTING (Prompt) Any hazardous area that is on the same floor as, and is in or abut, a primary means of escape or a sleeping room shall be protected by one of the following means: 1. Protection shall be an enclosure with a fire resistance rating of not less than 1 hour, with a self-closing or automatic closing fire door in accordance with 7.2.1.8 that has a fire protection rating of not less than 3/4 hour. 2. Protection shall be automatic sprinkler protection, in accordance with 33.2.3.5, and a smoke partition, in accordance with 8.4 located between the hazardous area and the sleeping area or primary escape route. Any doors in such separation shall be self-closing or automatic closing in accordance with 7.2.1.8. Other hazardous areas shall be protected in accordance with 33.2.3.2.5 by one of the following: 1. An enclosure having a fire resistance rating of not less than 1/2 hour, with a self-closing or automatic-closing door in accordance with 7.2.1.8 that is equivalent to not less than a 13/4 inch (4.4 cm) thick, solid-bonded wood core construction. 2. Automatic sprinkler protection in accordance with 33.2.3.5, regardless of enclosure. Areas with approved, properly installed and maintained furnaces and heating equipment, and cooking and laundry facilities are not classified as hazardous areas solely on basis of such equipment. Standard response sprinklers shall be permitted for use in hazardous areas in accordance with 33.2.3.2. 33.2.2.2.4, 33.2.3.2, 33.2.3.2.5


This STANDARD is not met as evidenced by:
Based on observation, the facility failed to maintain a hazardous area per the requirements of:

2012 NFPA 101, 33.2.3.2.4

This deficiency affects 1 hazardous room.

Findings include:

During a tour of the facility, the surveyor observed the Activity Closet (off of the Activity/Great Room) was approximately 65 square feet with multiple cardboard boxes and paper products and the corridor door did not have a self-closing device.

A member of the maintenance staff was present when this deficiency was identified.