Department of Health & Human Services

Centers for Medicare & Medicaid Services
Form Approved

OMB No. 0938-0391

Statement of Deficiencies (X1) Provider/Supplier/CLIA Identification Number 034526 (X3) Date Survey Completed 02/12/2020
Name of Provider or Supplier Paragon Physical Therapy And Rehab, Llc Street Address, City, State 2585 Miracle Mile, Suite 107, Bullhead City, AZ
For information on the provider's plan to correct this deficiency, please contact the provider or the state survey agency.
(X4) ID Prefix Tag Summary Statement of Deficiencies

(Each deficiency should be preceded by full regulatory or LSC identifying information)
E0013 Development of EP Policies and Procedures
CFR(s): 485.68(b)

§403.748(b), §416.54(b), §418.113(b), §441.184(b), §460.84(b), §482.15(b), §483.73(b), §483.475(b), §484.102(b), §485.68(b), §485.542(b), §485.625(b), §485.727(b), §485.920(b), §486.360(b), §491.12(b), §494.62(b). (b) Policies and procedures. [Facilities] must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must be reviewed and updated at least every 2 years. *[For LTC facilities at §483.73(b):] Policies and procedures. The LTC facility must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must be reviewed and updated at least annually. *Additional Requirements for PACE and ESRD Facilities: *[For PACE at §460.84(b):] Policies and procedures. The PACE organization must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must address management of medical and nonmedical emergencies, including, but not limited to: Fire; equipment, power, or water failure; care-related emergencies; and natural disasters likely to threaten the health or safety of the participants, staff, or the public. The policies and procedures must be reviewed and updated at least every 2 years. *[For ESRD Facilities at §494.62(b):] Policies and procedures. The dialysis facility must develop and implement emergency preparedness policies and procedures, based on the emergency plan set forth in paragraph (a) of this section, risk assessment at paragraph (a)(1) of this section, and the communication plan at paragraph (c) of this section. The policies and procedures must be reviewed and updated at least every 2 years. These emergencies include, but are not limited to, fire, equipment or power failures, care-related emergencies, water supply interruption, and natural disasters likely to occur in the facility's geographic area.


This STANDARD is not met as evidenced by:
Based on observation, interview and facility record review it was determined the facility failed to develop Emergency Preparedness policies and procedures based on an established EP plan, community risk assessment and communication plan, and failed to ensure the policies and procedures were reviewed and updated at least every 2 years.

Findings include:

On 2/12/2020 the EP tag requirements to be included in an EP plan were reviewed with the administrator. The facility did not have a documented EP, and the surveyors could not determine if policies and procedures were developed for the EP plan and reviewed.

The administrator stated in an interview on 2/12/2020 that she was unaware of new EP regulations for a CORF. It was determined that they did not have the facility's EP plan or that policies and procedures were developed for the EP plan.

Failure to develop policies and procedures based on an established EP plan may pose a potential risk of harm to the residents during an emergency.