| Statement of Deficiencies | (X1) Provider/Supplier/CLIA Identification Number 55C0001076 | (X3) Date Survey Completed 07/10/2019 |
| Name of Provider or Supplier Plastic Surg Assoc Of Orange County | Street Address, City, State 1310 Stewart Drive, Suite 610, Orange, CA | |
| For information on the provider's plan to correct this deficiency, please contact the provider or the state survey agency. | ||
| (X4) ID Prefix Tag | Summary Statement of Deficiencies
(Each deficiency should be preceded by full regulatory or LSC identifying information) |
| K0345 | Fire Alarm System - Testing and Maintenance CFR(s): NFPA 101 Fire Alarm Systems - Testing and Maintenance A fire alarm system is tested and maintained in accordance with an approved program complying with the requirements of NFPA 70, National Electric Code, and NFPA 72, National Fire Alarm and Signaling Code. Records of system acceptance, maintenance and testing are readily available. 9.6.1.3, 9.6.1.5, NFPA 70, NFPA 72 This STANDARD is not met as evidenced by: Based on interview and record review, the facility failed to ensure that the fire alarm system is maintained in reliable operating condition. This was evidenced by failing to provide documents to show that sensitivity testing of smoke detectors were conducted in the last two years. This could result in delay in notification of fire and possible harm to patients and staff. This affected two of two smoke compartments. NFPA 101, Life Safety Code, 2012 Edition 21.3.4.1 General. Ambulatory health care facilities shall be provided with fire alarm systems in accordance with Section 9.6, except as modified by 21.3.4.2 through 21.3.4.4. 9.6.1.3 A fire alarm system required for life safety shall be installed, tested, and maintained in accordance with the applicable requirements of NFPA 70, National Electrical Code, and NFPA 72, National Fire Alarm and Signaling Code, unless it is an approved existing installation, which shall be permitted to be continued in use. NFPA 72, National Fire Alarm And Signaling Code, 2010 Edition 10.18.3.1 A complete record of the tests and operations of each system shall be kept until the next test and for 1 year thereafter. 10.18.3.2 The record shall be available for examination and, if required, reported to the authority having jurisdiction. Archiving of records by any means shall be permitted if hard copies of the records can be provided promptly when requested. 14.4.5.3.1 Sensitivity shall be checked within 1 year after installation. 14.4.5.3.2 Sensitivity shall be checked every alternate year thereafter unless otherwise permitted by compliance with 14.4.5.3.3. 14.4.5.3.3 After the second required calibration test, if sensitivity tests indicate that the device has remained within its listed and marked sensitivity range (or 4 percent obscuration light gray smoke, if not marked), the length of time between calibration tests shall be permitted to be extended to a maximum of 5 years. 14.4.5.3.3.1 If the frequency is extended, records of nuisance alarms and subsequent trends of these alarms shall be maintained. 14.4.5.3.5 Unless otherwise permitted by 14.4.5.3.6, smoke detectors or smoke alarms found to have a sensitivity outside the listed and marked sensitivity range shall be cleaned and recalibrated or be replaced. Findings: During the review of records with the Nursing Director on 7/10/19, the fire alarm system records were requested and reviewed. At 11:37 a.m., the facility failed to provide documents to show that sensitivity testing was conducted on their smoke detectors for the last two years. During an interview with the Nursing Director, she stated that she believed the Building Maintenance staff was responsible for conducting the smoke detector sensitivity testing. |