| Statement of Deficiencies | (X1) Provider/Supplier/CLIA Identification Number 55C0001062 | (X3) Date Survey Completed 09/08/2026 |
| Name of Provider or Supplier Sacramento Eye Surgicenter | Street Address, City, State 3150 J Street, Sacramento, CA | |
| For information on the provider's plan to correct this deficiency, please contact the provider or the state survey agency. | ||
| (X4) ID Prefix Tag | Summary Statement of Deficiencies
(Each deficiency should be preceded by full regulatory or LSC identifying information) |
| K0521 | HVAC CFR(s): NFPA 101 HVAC Heating, ventilation, and air conditioning shall comply with 9.2 and shall be installed in accordance with the manufacturer's specifications. 20.5.2.1, 21.5.2.1, 9.2 This STANDARD is not met as evidenced by: Based on document review and interview, the facility failed to maintain the HVAC system. This was evidenced by missing records for the required test and inspection for the facility's smoke dampers. This could result in the spread of smoke throughout smoke compartments in the event of a fire. This affected 16 of 16 patients and four of four smoke compartments. NFPA 101, Life Safety Code, 2012 Edition 21.5.2 Heating, Ventilating, and Air-Conditioning. 21.5.2.1 Heating, ventilating, and air-conditioning shall comply with the provisions of Section 9.2 and shall be installed in accordance with the manufacturer's specifications, unless otherwise modified by 21.5.2.2. 9.2.1 Air-Conditioning, Heating, Ventilating Ductwork, and Related Equipment. Air-conditioning, heating, ventilating ductwork, and related equipment shall be in accordance with NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, or NFPA 90B, Standard for the Installation of Warm Air Heating and Air-Conditioning Systems, as applicable, unless such installations are approved existing installations, which shall be permitted to be continued in service. NFPA 90A, Standard for the Installation of Air-Conditioning and Ventilating Systems, 2012 Edition 5.4.8 Maintenance. 5.4.8.1 Fire dampers and ceiling dampers shall be maintained in accordance with NFPA 80, Standard for Fire Doors and Other Opening Protectives. NFPA 80, Standard for Fire Doors and Other Opening Protectives, 2010 Edition 19.4* Periodic Inspection and Testing. 19.4.1 Each damper shall be tested and inspected 1 year after installation. 19.4.1.1 The test and inspection frequency shall then be every 4 years, except in hospitals, where the frequency shall be every 6 years. 19.4.3 Full unobstructed access to the fire or combination fire/ smoke damper shall be verified and corrected as required. 19.4.4 If the damper is equipped with a fusible link, the link shall be removed for testing to ensure full closure and lock-inplace if so equipped. 19.4.5 The operational test of the damper shall verify that there is no damper interference due to rusted, bent, misaligned, or damaged frame or blades, or defective hinges or other moving parts. 19.4.6 The damper frame shall not be penetrated by any foreign objects that would affect fire damper operations. 19.4.7 The damper shall not be blocked from closure in any way. 19.4.8 The fusible link shall be reinstalled after testing is complete. 19.4.8.1 If the link is damaged or painted, it shall be replaced with a link of the same size, temperature, and load rating. 19.4.9 All inspections and testing shall be documented, indicating the location of the fire damper or combination fire/ smoke damper, date of inspection, name of inspector, and deficiencies discovered. 19.4.9.1 The documentation shall have a space to indicate when and how the deficiencies were corrected. 19.4.10 All documentation shall be maintained and made available for review by the AHJ. Findings: During document review and interview with staff on 9/8/26, the smoke damper inspection and testing records were requested. At 10:54 a.m., the facility failed to provide records to show that the four-year smoke damper testing had been conducted. The date of the last smoke damper testing was unknown. During a concurrent interview, Staff 1 confirmed the finding and stated that she was under the impression that the damper testing had been conducted during the annual fire alarm system (FAS) test. The annual FAS testing record dated 1/10/25 failed to show damper testing being conducted. |