| Statement of Deficiencies | (X1) Provider/Supplier/CLIA Identification Number 55C0001059 | (X3) Date Survey Completed 04/10/2019 |
| Name of Provider or Supplier Fort Sutter Surgery Center, A Ca Limited Partnership | Street Address, City, State 2801 K Street, Suite 525, Sacramento, CA | |
| For information on the provider's plan to correct this deficiency, please contact the provider or the state survey agency. | ||
| (X4) ID Prefix Tag | Summary Statement of Deficiencies
(Each deficiency should be preceded by full regulatory or LSC identifying information) |
| K0345 | Fire Alarm System - Testing and Maintenance CFR(s): NFPA 101 Fire Alarm Systems - Testing and Maintenance A fire alarm system is tested and maintained in accordance with an approved program complying with the requirements of NFPA 70, National Electric Code, and NFPA 72, National Fire Alarm and Signaling Code. Records of system acceptance, maintenance and testing are readily available. 9.6.1.3, 9.6.1.5, NFPA 70, NFPA 72 This STANDARD is not met as evidenced by: Based on observation, document review, and interview, the facility failed to maintain the smoke detection devices. This was evidenced by the absence of a smoke detector sensitivity testing report. This affected all patients, and could result in a smoke detector malfunction in the event of a fire. NFPA 101 Life Safety Code, 2012 Edition 21.3.4 Detection, Alarm, and Communications Systems. 21.3.4.1 General. Ambulatory health care facilities shall be provided with fire alarm systems in accordance with Section 9.6, except as modified by 21.3.4.2 through 21.3.4.4. 9.6.1.3 A fire alarm system required for life safety shall be installed, tested, and maintained in accordance with the applicable requirements of NFPA 70, National Electrical Code, and NFPA 72, National Fire Alarm and signaling Code, unless it is an approved existing installation, which shall be permitted to be continued in use. NFPA 72 National Fire Alarm, 2010 edition 14.4.5.3.1 Sensitivity shall be checked within 1 year after installation. 14.4.5.3.2 Sensitivity shall be checked every alternate year thereafter unless otherwise permitted by compliance with 14.4.5.3.3. 14.4.5.3.3 After the second required calibration test, if sensitivity tests indicate that the device has remained within its listed and marked sensitivity range (or 4 percent obscuration light gray smoke, if not marked), the length of time between calibration tests shall be permitted to be extended to a maximum of 5 years. 14.4.5.3.3.1 If the frequency is extended, records of nuisance alarms and subsequent trends of these alarms shall be maintained. 14.4.5.3.3.2 In zones or in areas where nuisance alarms show any increase over the previous year, calibration tests shall be performed. 14.4.5.3.4 To ensure that each smoke detector or smoke alarm is within its listed and marked sensitivity range, it shall be tested using any of the following methods: (1) Calibrated test method (2) Manufacturer ' s calibrated sensitivity test instrument (3) Listed control equipment arranged for the purpose (4) Smoke detector/fire alarm control unit arrangement whereby the detector causes a signal at the fire alarm control unit where its sensitivity is outside its listed sensitivity range (5) Other calibrated sensitivity test methods approved by the authority having jurisdiction. Findings: During a facility tour, document review, and interview with staff on 4/10/19, records for smoke detector sensitivity were requested. At 12:00 p.m., smoke detection devices were observed throughout the facility, and at the two fire alarm panels. The facility was not able to provide a current smoke detector sensitivity testing report. The last smoke detector sensitivity testing was unknown. Upon interview, Staff 1 stated that they would be contacting the fire alarm system vendor regarding the report. |